Designing total-harmonic-distortion (THD) measurement into a system usually involves a notch filter and a broadband ac measurement. The problem with this technique is that it measures both THD and noise. DSP-based test equipment can calculate just the THD, but this isn't practical for most portable equipment.

However, system designers can add THD measurement capability by using a bank of band-pass filters set at the harmonics of the fundamental, along with a notch filter. This approach doesn't require a microcontroller.

Figure 1 shows a circuit that measures THD directly, without noise. The MSHN1 is a switched-capacitor high-pass/notch filter that features three settings for the notch filter (narrow, wide, and deep). The MSFS5 is a switched-capacitor low-pass/ band-pass filter.

The output of the MSHN1 before the bank of MSFS5s provides the THD + noise signal needed for measurement. By setting the filter to a one-sixth-octave filter and generating clocks at 100 times the harmonic frequencies, the summed outputs supply a THD output that can be measured directly. Because three of the filter clocks are at divide-by-three, divide-by-five, and divide-by-six, the clock generator is more complex than a simple 74HC4040 binary divider. The 74HC163N, 74HC390, and 74HC393 generate the clocks for the third-and fifth-harmonic filters.

The TI TLC081 op amp sums the six band-pass filter outputs to generate the single summed signal. Figure 2 illustrates the op-amp output.

Depending on the complexity of the THD meter, the TLC081's output connects either to the analog input of the display controller, or to an LM3914 linear dot/bar display driver for a simple 10-segment THD display of the input waveform.


Reprints   Printer-Friendly  Email this Article  RSS    Font Size   What's This?


  • Network-On-Chip Tools Arrive for The Masses
  • Tackling System Design Challenges Through Early Verification
  • ESL Tools Take Center Stage As Designers Move Up
  • Parasitic Extraction Tool Targets Next-Generation Custom ICs
  • Synopsys Jumps Into ESL-Synthesis Pool
  • Verify Control Systems Before Committing To Hardware
  • You're Using How Many FPGAs?
  • Tool Up For The FPGA Blitz
    1) Build A Smart Battery Charger Using A Single-Transistor Circuit
    (177 views today)
    2) Hot Hands For Some Cool Rock: Motion Sensing Meets Audio Engineering
    (168 views today)
    3) What's All This Transimpedance Amplifier Stuff, Anyhow? (Part 1)
    (72 views today)
    4) GPS-Derived Grandmaster Clock Delivers Ultra-Precise Time And Frequency Sync
    (72 views today)
    5) Downconverting Mixers Lower Power Consumption While Improving Performance
    (56 views today)
    ALL TOP 20



    POST YOUR COMMENTS HERE
    Name:

    Email:
    Your Comments:

    Enter the text from the image below


    Please refresh the page if you have trouble reading this text.

    Search Electronic Design
         
      
     
    Email Newsletter
    Sponsored By:
    Electronic Design UPDATE provides readers with late-breaking news, opinions from industry experts, and timely technology stories. It's a unique opportunity to get your product message in front of engineers, engineering managers, and corporate managers while they're reading about critical information online.

    Enter Email to Subscribe
      

    Electronic Design Europe Electronic Design China EEPN Power Electronics Auto Electronics Microwaves & RF
    Mobile Dev & Design Schematics Find Power Products Military Electronics EE Events Related Resources