Part 2 of this series showed how a dual-slope integrator could fix the major limitations of a single slope converter, and I received several e-mails in response (August 28, p. 18, ED Online 19512). For example, Harry Bissel of WTC questioned my choice of polyester capacitors for low dielectric absorption.
“I don’t believe that ‘Polyeste’ belongs in your list of good integration capacitor types,” he wrote. “Its dielectric absorption is an order of magnitude higher than the ‘good’ poly types. I would recommend that people NOT use Polyester (a.k.a. Mylar) for a critical component like this.”
Harry is correct that Mylar isn’t as good as many of the other types of capacitors. This conversation fondly takes me back to a time spent—with coworkers, of course, not family—discussing the benefits of different poly cap types over a pitcher of beer. It is hard to believe so much passion can be generated by a simple two-lead component. Still, I would prefer a solution that did not require the use of any “poly cap.”
KNOW YOUR LIMITS Two major limitations of the dual-slope topology are comparator sensitivity and dielectric absorption. Suppose that instead of waiting until the end of the integration period to start precisely removing the charge, the references are incrementally subtracted during the integration time. Figure 1 shows a plot of this technique along with that of a dual-slope integrator. Both have an input of 0.3 V, 100-ms integration period, and references of ±1 V.
The dual slope integrates the 0.3-V input for 100 ms and then applies the –1-V reference to start removing the acquired charge. It takes 30 ms to move the integrator output back to zero. Like the dual slope, the incremental method also integrates the input for a fixed time. Where it differs is that during the integration time, the references are constantly applied to move the output back toward zero.
For this example, the 1-V reference is subtracted 65% of the time and the –1-V reference is subtracted 35% of the time, resulting in an average of 0.3 V. The output is said to have a density of 65%. Note that the incremental method no longer requires a reintegration period.
With the charge immediately removed, there is no longterm charge to be absorbed. This eliminates the need for a poly cap. Instead, a three-cent NPO ceramic cap will suffice. For a dual slope, the integrator slope had to be set to keep the integrator in range for the whole integration period for the maximum input signal. For the incremental, with its references constantly moving the integrator back toward zero, it has to only remain within range for each clock cycle.
This allows for a significant increase in integrator gain, reducing the sensitivity requirement for the comparator. For a dual slope, increasing the integration time requires reducing the integrator slope. This is not the case for the incremental. The integration time can easily be increased with the integrator output guaranteed to stay in range. Figure 2 shows an incremental converter. It is called ratiometric because it uses the power supplies as references. It sounds fancier than “we didn’t provide real references.”
The supplies are VDD and ground. The analog ground (AGND) for this system is halfway between the supplies or 0.5 VDD. For a 5-V supply and all signals referred to AGND, VREF+ is 2.5 V and VREF– is –2.5 V. The resistor and capacitor values were selected to set a slope guaranteed to stay in range for a 1-MHz sample clock.
The comparator is used to determine which reference is fed back. This negative feedback causes the output to do whatever it can to make the inputs match. So the average of the input voltages will equal the average of references:
Please refresh the page if you have trouble reading this text.
Search Electronic Design
Email Newsletter
Sponsored By:
Electronic Design UPDATE provides readers with late-breaking news, opinions from industry experts, and timely technology stories. It's a unique opportunity to get your product message in front of engineers, engineering managers, and corporate managers while they're reading about critical information online.