Since the introduction of solid-state relays some decades ago, the debate over which is better, solid-state relays (SSRs) or electromechanical relays (EMRs), has gone on. The general answer is neither, as each one has good and bad points. But in terms of specific application requirements, clear winners emerge.

When used as intended, SSRs will perform indefinitely, usually outlasting the equipment in which they're installed. They operate silently and produce little electrical interference. SSRs will function over a wide range of input voltages and consume little power even at the high-voltage limit. They don't produce any arc, making them suitable for hazardous environments. Most ac switching types employ "zero-voltage crossover," which minimizes surge currents. SSRs have no moving parts, so physical shock, vibration, or changes in altitude won't affect them.

SSRs aren't relays at all, but rather electronic circuits. Typically, an SSR's input consists of an opto-isolator, while its output is a triac, SCR, or FET. One negative aspect of an SSR is that semiconductors are never completely on or off. In the on-state, substantial resistance is present, which can lead to significant heat generation when current is flowing. So SSRs must be mounted on heatsinks, often several times the relay's weight. They're sensitive to ambient heat and must be derated if used in hot environments or with less than optimal heatsinks.

In some applications, on-state voltage drop can cause problems for loads that are sensitive to reduced voltage. When off, the resistance goes up, but the circuit path isn't completely open. Off-state resistance permits enough current flow at higher voltages to be objectionable, even dangerous.

Under normal service conditions, SSRs seldom fail. But when they do, they nearly always fail shorted. The user might not realize that the relay has failed, depending on the load being controlled—or no longer being controlled. When exposed to surges or spike voltages on the controlled line, SSRs may conduct for as much as one half-cycle after the surge has stopped. Most require a minimum load or they won't function, and only switch ac or dc, not both.

While some solid-state packages are billed as having multiple poles, those we have seen are individual SSRs with their inputs in parallel, mounted in a single package. One concern is what happens if just one side malfunctions. That may be acceptable, perhaps even desirable, if the relay is controlling separate loads. But it could be catastrophic in other situations.

When an EMR expires, it's usually due to coil failure. While contacts can weld if heavily overloaded, this is a rare occurrence for a properly designed application, and it is usually self-evident. EMRs can switch any ac or dc load up to their maximum rating. Their contact resistance diminishes as the load increases, eliminating any need for heatsinking. Although EMRs require substantial coil power, they operate at full load over a wide temperature range.

When the contacts are open, there's nearly total line-to-load isolation that can only be bridged if the applied voltage exceeds the dielectric strength of the relay. Most EMRs come with multiple poles and can control multiple voltages and circuits simultaneously.

Like all mechanical devices, EMRs have finite life expectancies. At some point, even the best designed, constructed, and properly selected EMR will stop functioning. In many cases, though, the equipment employing the relay wears out before the EMR.

With contacts that physically open and close, EMRs arc when they interrupt current. This is usually beneficial to the relay, but it may cause nearby equipment to malfunction if it's sensitive to radio frequency interference (RFI). On the other hand, electromagnetic interference (EMI) caused by relays isn't an issue unless EMI-sensitive equipment is installed in close proximity. Good EMRs are designed to contain their electromagnetic fields. Otherwise, they would be highly inefficient.

SSRs are indicated where the primary requirement is the ability to perform for tens of millions of operations, or more. Also, they're often specified where silence is important. If arcing or RFI must be avoided at all costs, SSRs are better.

In applications where a circuit must be completely on or off with minimal on-state voltage drop, or no danger of injury or damage from leakage current, the electromechanical relay is the only choice. EMRs also are best if heavy surge currents or spike voltages are anticipated or known to occur. In some applications, the relay type selected is mostly a matter of personal preference. But avoid the pitfall of trying to adapt one type to execute a job better performed by the other. This advice is often ignored because of personal bias or a reluctance to ask for help. Many relay manufacturers implement applications specialists who welcome the opportunity to help select the best product for the particular circumstances.




Reprints     Printer-Friendly    Email this Article    RSS        Font Size     What's This?


  • Network-On-Chip Tools Arrive for The Masses
  • Tackling System Design Challenges Through Early Verification
  • ESL Tools Take Center Stage As Designers Move Up
  • Parasitic Extraction Tool Targets Next-Generation Custom ICs
  • Synopsys Jumps Into ESL-Synthesis Pool
  • Verify Control Systems Before Committing To Hardware
  • You're Using How Many FPGAs?
  • Tool Up For The FPGA Blitz
    1) Build A Smart Battery Charger Using A Single-Transistor Circuit
    (180 views today)
    2) Hot Hands For Some Cool Rock: Motion Sensing Meets Audio Engineering
    (166 views today)
    3) What's All This Transimpedance Amplifier Stuff, Anyhow? (Part 1)
    (72 views today)
    4) GPS-Derived Grandmaster Clock Delivers Ultra-Precise Time And Frequency Sync
    (70 views today)
    5) Downconverting Mixers Lower Power Consumption While Improving Performance
    (55 views today)
    ALL TOP 20







    POST YOUR COMMENTS HERE

    Name:

    Email:
    Rate this article:

     less useful more useful 
    1
    2
    3
    4
    5
    Your Comments:

    Enter the text from the image below




    Please refresh the page if you have trouble reading this text.
    (Acceptable Use Policy)
     
     

    PartFinder

    Find real-time pricing, stock status, same-day/next-day shipping options and more. Brought to you by Digi-Key. Go to PartFinder.    
    GlobalSpec

    PART SEARCH :
    Powered by: GlobalSpec - The Engineering Search Engine
    Sponsored Links

    Electronic Design Europe Electronic Design China EEPN Power Electronics Auto Electronics Microwaves & RF
    Mobile Dev & Design Schematics Find Power Products Military Electronics EE Events Related Resources