In a classic zero-current/zero-voltage (ZC/ZV) converter, the amplitude of the resonant circuits signal can be hundreds of volts. Compare that to a sine amplitude converter (SAC), where the oscillation is just a few volts peak to peak. In the former case, the high amplitude is required because the classic ZC/ZV converter processes energy serially.
The SAC depends on minimization of transformer leakage inductance to minimize its Q. This may seem counter-intuitive given that oscillator design typically requires high values of Q. However, in the case of the SAC, the goal is to minimize the energy stored in the transformers leakage inductance. Thats because the more energy stored in the leakage inductance, the slower the response of the converter and the greater the transformers resistance and its losses.
In the SAC, lowering the Q actually leads to higher conversion efficiency, despite the fact that the fraction of energy lost in the tank circuit rises as its Q is lowered. Although tank circuit losses rise in proportion to 1/Q, the total amount of energy stored in the tank circuit dropsmore rapidlyin proportion to Q2. In other words, because much less energy is stored in the tank circuit at lower Q values, you can afford to lose a greater percentage of this energy and still achieve a net decrease in converter losses.
But Q can only be lowered to a point. At the very least, Q must have a value greater than 1 or the SAC will not oscillate. In practice, the Q can only be reduced to 2 or 3, otherwise the oscillation will cease to be sinusoidala basic requirement for ZC switching.
Comparing Q and Stored Energy The Q associated with power-transformer leakage inductance and the energy stored in that leakage inductance vary according to the power conversion technology employed. The table indicates the resulting Q and energy storage levels, when three styles of dc-dc converters are used to generate 200 W of output. Although the pulse width modulation (PWM) converter and the SAC exhibit similar levels of Q, there is much less energy stored in the power transformer of the sine amplitude converter.
That reflects the order-of-magnitude difference in switching frequencies between the two styles of converter. Due to switching losses, the PWM converter switches at the lower frequency. That, in turn, requires a larger number of turns in the power transformer. Those extra turns and the lower switching frequency account for greater leakage inductance in the power transformer, which leads to the higher level of energy storage in the PWM converter.
In the traditional resonant forward converter with ZC/ZV switching, the leakage inductance is intentionally made high to maximize the energy stored in the transformer.
Very interesting approach. We have used bidirectional non-resonant converter with a similar approach. However. in order to control more closely the leakage inductance and reduce the commutation frequency, we added a serial inductor of known value.
Well writen and of great interest.
Alain St-Jacques -November 24, 2003
Your Comments:
Enter the text from the image below
Please refresh the page if you have trouble reading this text.
Search Electronic Design
Email Newsletter
Sponsored By:
The Find Power Products monthly newsletter brings you the most important new developments within the world of power design. The newsletter includes exerpts from industry leader Sam Davis's exclusive blog, as well as overviews of the latest new products.
Enter Email to Subscribe
Web Seminar
Sponsored By:
Title: Exploring How Good GUIs Drive Adoption in the Digital Power Management Space