Part 2 of this series showed how a dual-slope
integrator could fix the major limitations of
a single slope converter, and I received several
e-mails in response (August 28, p. 18, ED
Online 19512). For example, Harry Bissel of WTC questioned
my choice of polyester capacitors for low dielectric absorption.
“I don’t believe that ‘Polyeste’ belongs in your list of good
integration capacitor types,” he wrote. “Its dielectric absorption
is an order of magnitude higher than the ‘good’ poly types.
I would recommend that people NOT use Polyester (a.k.a.
Mylar) for a critical component like this.”
Harry is correct that Mylar isn’t as good as many of the other
types of capacitors. This conversation fondly takes me back to a
time spent—with coworkers, of course, not family—discussing
the benefits of different poly cap types over a pitcher of beer. It
is hard to believe so much passion can be generated by a simple
two-lead component. Still, I would prefer a solution that did
not require the use of any “poly cap.”
KNOW YOUR LIMITS
Two major limitations of the dual-slope topology are comparator
sensitivity and dielectric absorption. Suppose that
instead of waiting until the end of the integration period to
start precisely removing the charge, the references are incrementally
subtracted during the integration time. Figure 1
shows a plot of this technique along with that of a dual-slope
integrator. Both have an input of 0.3 V, 100-ms integration
period, and references of ±1 V.
The dual slope integrates the 0.3-V input for 100 ms and
then applies the –1-V reference to start removing the acquired
charge. It takes 30 ms to move the integrator output back to
zero. Like the dual slope, the incremental method also integrates
the input for a fixed time. Where it differs is that during
the integration time, the references are constantly applied to
move the output back toward zero.
For this example, the 1-V reference is subtracted 65% of
the time and the –1-V reference is subtracted 35% of the time,
resulting in an average of 0.3 V. The output is said to have a
density of 65%. Note that the incremental method no longer
requires a reintegration period.
With the charge immediately removed, there is no longterm
charge to be absorbed. This eliminates the need for a
poly cap. Instead, a three-cent NPO ceramic cap will suffice.
For a dual slope, the integrator slope had to be set to keep the
integrator in range for the whole integration period for the
maximum input signal. For the incremental, with its references
constantly moving the integrator back toward zero, it has to
only remain within range for each clock cycle.
This allows for a significant increase in integrator gain,
reducing the sensitivity requirement for the comparator. For
a dual slope, increasing the integration time requires reducing
the integrator slope. This is not the case for the incremental.
The integration time can easily be increased with the integrator
output guaranteed to stay in range. Figure 2 shows an
incremental converter. It is called ratiometric because it uses the
power supplies as references. It sounds fancier than “we didn’t
provide real references.”
The supplies are VDD and ground. The analog ground
(AGND) for this system is halfway between the supplies or
0.5 VDD. For a 5-V supply and all signals referred to AGND,
VREF+ is 2.5 V and VREF– is –2.5 V. The resistor and capacitor
values were selected to set a slope guaranteed to stay in range
for a 1-MHz sample clock.
The comparator is used to determine which reference is fed
back. This negative feedback causes the output to do whatever
it can to make the inputs match. So the average of the input
voltages will equal the average of references:
VIN = DensityOUT × VREF+ + (1 – DensityOUT) × VREF–
All that’s needed to calculate the input voltage is to measure the
density. Figure 3 shows the hardware that will do this.