Inexpensive "Reflectometer" Locates An Open Circuit Along A Cable

Jan. 22, 2001
Faults such as opens, shorts, or mismatches can be precisely located along the length of a cable by using a time-domain reflectometer. This device launches a rectangular pulse toward the cable's end and waits for an echo signal. The time between the...

Faults such as opens, shorts, or mismatches can be precisely located along the length of a cable by using a time-domain reflectometer. This device launches a rectangular pulse toward the cable's end and waits for an echo signal. The time between the start of the pulse and the arrival of the echo is then converted in terms of distance, allowing the fault to be accurately located. An oscilloscope is typically used to obtain the elapsed time reading.

To detect ordinary open circuits along the cable, however, a simple, low-cost 555 timer IC operating in astable mode can be employed. Coaxial cables have distributed capacitances per unit length, which may be used to replace an actual capacitor (see the figure).

The LED will blink at a rate inversely related to the length of the cable, or at a frequency = 1.443/\[(RA + 2RB)C\]. For a 45-meter RG-58/U cable, the LED will flash at f1 = 1.67 Hz. When an open circuit is introduced at L2 = 25 meters from the IC, the LED will blink at about f2 = 3 Hz. By observing the increase in the LED's flash rate, the location (L2) of the open-circuit can be determined using the formula L2/L1 = f1/f2, where L1 = 45 meters.

For other lengths of cable, the value of RA and RB may need to be modified to find the values that make visual checking possible. Alternatively, the output of the 555 can be sent to a frequency counter for a more precise reading.

Sponsored Recommendations

Understanding Thermal Challenges in EV Charging Applications

March 28, 2024
As EVs emerge as the dominant mode of transportation, factors such as battery range and quicker charging rates will play pivotal roles in the global economy.

Board-Mount DC/DC Converters in Medical Applications

March 27, 2024
AC/DC or board-mount DC/DC converters provide power for medical devices. This article explains why isolation might be needed and which safety standards apply.

Use Rugged Multiband Antennas to Solve the Mobile Connectivity Challenge

March 27, 2024
Selecting and using antennas for mobile applications requires attention to electrical, mechanical, and environmental characteristics: TE modules can help.

Out-of-the-box Cellular and Wi-Fi connectivity with AWS IoT ExpressLink

March 27, 2024
This demo shows how to enroll LTE-M and Wi-Fi evaluation boards with AWS IoT Core, set up a Connected Health Solution as well as AWS AT commands and AWS IoT ExpressLink security...

Comments

To join the conversation, and become an exclusive member of Electronic Design, create an account today!